AQ Electric tests and commissions solar plants across the MENA region, and that field work gives our engineering team an unusual vantage point: we see, string by string, which design decisions hold up in operation and which ones turn into permanent losses, failed acceptance tests, or expensive retrofits. Most of a solar plant’s lifetime performance is fixed on paper long before the first pile is driven. This article explains what solar engineering consultation services cover — feasibility and preliminary design, detailed electrical and mechanical design, energy yield assessment, bills of materials, tender and proposal support, and independent design review — and how developers and EPC contractors can use them to win projects, protect yield, and pass acceptance first time.
Key takeaways
Solar engineering consultation services provide the technical design and advisory work behind a PV project: site assessment and feasibility, preliminary and detailed electrical and mechanical design, PVsyst energy yield reports, single-line diagrams and layouts, bills of materials, tender documents and technical proposals, and independent design review. Developers use them to define bankable projects and select contractors; EPC contractors use them as back-office design capacity to price and win bids. Design choices — string sizing, inverter loading, cable sizing, tracker and structure selection, monitoring, and grid compliance — are locked in for 25 years or more, so independent, field-informed engineering is one of the highest-value investments in a solar project.
What Are Solar Engineering Consultation Services?
Solar engineering consultation services are the design, analysis, and advisory work that turns a site and a business case into a buildable, bankable PV plant. They fall into three broad groups:
- Design services — feasibility and preliminary design, detailed electrical and mechanical design, energy yield reports, bills of materials, and drawings, often delivered as “back-office” capacity for EPC contractors and developers.
- Tendering and proposal services — bid documents, technical proposals, equipment selection, and cost analysis for contractors bidding on projects, or technical specifications and bid evaluation for owners procuring them.
- Consultation and review — independent design review, technical advice through construction and commissioning, and support for the owner across the project lifecycle.
Owner-side lifecycle support is covered in AQ Electric’s article on the owner’s engineer for solar PV projects. This article focuses on the design, yield, and tender work at the heart of solar engineering consultation services.
Why Engineering Decides Lifetime Yield
A solar plant is designed once and operated for decades. Choices made in the design office — how many modules per string, how much DC capacity per inverter, which cable sizes, which structures or trackers, where to place monitoring sensors — cannot easily be changed once the plant is built.
Raptor Maps’ 2026 Global Solar Report found an average power loss of 4.46% already present at commissioning across its dataset, and that trackers alone accounted for just under 14% of observed power loss in operating plants. Some of those losses originate in construction and equipment, but many trace back to design decisions and to designs that were never independently checked. Good solar engineering consultation services reduce those losses at the cheapest possible point: before procurement and construction.
Design Shapes Acceptance, Too
Design also determines whether the plant can pass its acceptance tests. Engineering firm Burns & McDonnell has documented how inverter clipping on tracking plants with DC-to-AC ratios above roughly 1.3–1.4 can remove most usable midday data from capacity tests. A design that optimises energy without considering how performance will be tested can leave the EPC struggling to prove its guarantees at handover.
Feasibility and Preliminary Design
The feasibility stage answers whether a project makes sense and what it should look like. Typical outputs include:
- Site assessment — topography, access, soil and drainage, shading, and constraints such as setbacks and easements.
- Solar resource assessment — long-term irradiance data from satellite sources and, where available, on-site measurements.
- Technology options — fixed-tilt or single-axis trackers, monofacial or bifacial modules, central or string inverters.
- Preliminary layout and capacity — how much DC and AC capacity the site can accommodate.
- Grid connection options — voltage level, substation needs, and the grid operator’s requirements.
- Preliminary energy yield — a PVsyst simulation, single-line diagram, and layout to support early investment decisions.
Resource data drives everything that follows. Where on-site measurements are used to validate satellite data, the quality of the instruments matters; AQ Electric’s sister company EE Electronics supplies solar irradiance meters in Jordan for field measurement.
Detailed Electrical and Mechanical Design
Detailed design converts the concept into construction drawings and specifications. The key areas include:
| Design area | Key decisions | What goes wrong if it is poor |
|---|---|---|
| String configuration | Modules per string checked against the full site temperature range and inverter voltage window | Over-voltage on cold mornings or under-voltage in summer heat |
| Inverter selection and loading | Inverter type, DC-to-AC ratio, MPPT configuration | Excessive clipping, lost energy, difficult capacity tests |
| Cabling | DC and AC cable sizing, routing, voltage drop, derating for heat and burial | Losses, overheating, and cable faults |
| Protection and earthing | Fusing, surge protection, earthing and lightning protection | Safety risks, equipment damage, nuisance trips |
| MV and substation | Transformer sizing, MV collection layout, switchgear, protection settings | Bottlenecks, grid compliance failures, single points of failure |
| Structures and trackers | Foundation design, wind loads, tracker stow strategy, row spacing | Structural failures, shading losses, tracker downtime |
| Monitoring | Irradiance and temperature sensors, metering, SCADA architecture | Performance that cannot be measured or verified |
Designs should follow the applicable standards, including IEC 62548 for PV array design requirements, IEC 60364-7-712 for PV installations, and IEC 61724-1 for performance monitoring. Earthing design depends on measured soil resistivity; EE Electronics explains the measurement methods in its article on the earth resistance test. AQ Electric explains the downstream components in its articles on solar inverters in utility-scale PV plants, solar power plant transformers, and solar string wiring.
Energy Yield Assessment and PVsyst Reports
The energy yield assessment is the bridge between engineering and finance. It estimates how much energy the plant will produce, usually expressed as a P50 value (expected to be exceeded half the time) and P90 value (expected to be exceeded nine years out of ten), and it underpins the financial model, the PPA, and the lender’s sizing of debt.
PVsyst is the industry’s most widely used simulation software for this work. A credible PVsyst report sets out every assumption in the loss chain, including:
- Irradiance and weather data — source, period, and uncertainty.
- Module performance — the PAN file, temperature coefficients, and bifacial parameters.
- Temperature losses — usually the largest loss in hot climates.
- Soiling, shading, and mismatch — site-specific assumptions, not defaults.
- Electrical losses — cables, inverters, transformers, and clipping.
- Availability and degradation — realistic downtime and long-term degradation rates.
For bifacial plants, the rear-side gain depends heavily on ground albedo and row geometry; NREL notes that bifacial gain on single-axis trackers typically ranges from 5% to 12%. Optimistic assumptions in any of these inputs produce a yield forecast the plant will never meet. Independent review of the yield assessment is a standard lender requirement; AQ Electric explains why in its articles on the lender’s technical advisor for solar PV projects and solar bankability testing.
Bills of Materials and Documentation
A complete bill of materials defines every component, its specification, and its quantity, and becomes the basis for procurement, cost estimates, and quality control. Precise specifications matter: under a fixed-price contract, anything the specification does not require, the supplier is not obliged to provide.
Documentation is equally important. Approval packages for authorities and grid operators, construction drawings, and as-built drawings at handover are the plant’s permanent technical record. Poor as-built documentation makes every future fault-finding exercise, inspection, and extension slower and more expensive.
Tender and Proposal Support
For EPC Contractors
EPCs often need to price several tenders at once with limited internal design capacity. Solar engineering consultation services can supply back-office design and proposal support: bid documents prepared to the tender’s specifications, technical proposals covering design concept, equipment selection, and compliance, and cost estimation including CAPEX and OPEX analysis. A technically strong, compliant proposal improves both the chance of winning and the margin on the project once won.
For Developers and Owners
On the owner’s side, consultants prepare technical specifications and employer’s requirements, evaluate bids technically, compare equipment and design proposals, and identify gaps or risks in contractors’ offers. The quality of the tender documents largely determines the quality of the plant the owner receives.
Independent Design Review
Even an experienced design team benefits from an independent check. Design review catches errors when they cost almost nothing to correct. Common findings include:
- String voltages outside the inverter or module limits at the site’s extreme temperatures.
- Inverter loading that clips more energy than the yield model assumes, or that complicates capacity testing.
- Undersized cables once heat and burial derating are applied.
- Optimistic yield assumptions for soiling, availability, albedo, or degradation.
- Inadequate earthing, surge, or lightning protection for the site’s soil and exposure.
- Monitoring that cannot support performance guarantees — too few sensors, wrong positions, or no rear-irradiance measurement on bifacial plants.
- Grid code gaps — reactive power or fault ride-through capability that does not meet the operator’s requirements.
Review is equally valuable when a project is bought or refinanced; AQ Electric covers that context in its article on solar PV technical due diligence.
Designing for Gulf and MENA Conditions
Solar engineering consultation services in the region must design for conditions that temperate-market defaults do not capture.
Heat
With a module power temperature coefficient of the order of −0.3% per °C, every degree of operating temperature matters. Heat affects string voltage windows, inverter derating, cable ampacity, and transformer loading, and must be reflected in both the electrical design and the yield model.
Dust, Sand, and Wind
Soiling assumptions should be site-specific and linked to a realistic cleaning strategy, with access designed in from the start. Sand and wind affect tracker stow strategies, structural loads, and equipment enclosures.
Coastal Corrosion
Plants near the Gulf, Red Sea, or Arabian Sea coasts need corrosion protection for structures, enclosures, and connections appropriate to their exposure.
Grid Codes
Grid requirements are increasingly demanding. The Saudi Arabian Grid Code, for example, requires power park modules to supply or absorb reactive power within ±0.33 of rated active power above 20% output, and Egypt’s EETC updated its guidelines in 2024 to require dynamic studies with vendor models and insulation coordination within electromagnetic transient studies. These requirements must be designed in, not added at commissioning. AQ Electric covers both markets in its articles on solar PV testing services in Saudi Arabia and solar testing services in Egypt, and the regional pipeline in its MENA solar market outlook.
From Design to Commissioning
The design is also the reference against which the plant is tested. Expected string voltages and currents, protection settings, cable test values, and the performance model used in acceptance tests all come from design documentation. When design and testing are disconnected, commissioning teams waste time reconciling results with drawings that do not match what was built.
A field-informed design team writes designs that are easy to test and verify, and passes complete design data to the commissioning team. AQ Electric explains the downstream steps in its articles on the solar PV commissioning process, IEC 62446-1, the solar performance ratio, and MV cable testing in solar PV plants. For EPCs, the link between design and testing is covered in its article on testing services for solar EPC contractors.
How to Choose a Solar Engineering Consultant
When selecting a provider of solar engineering consultation services, look for:
- Utility-scale experience — named projects of comparable size and technology.
- Field feedback — engineers who also test, commission, or operate plants, and know which designs work in practice.
- Regional knowledge — climate, grid codes, utilities, and approval processes in the country of the project.
- Transparent yield modelling — documented assumptions and sensitivity analysis, not a single headline number.
- Standards competence — IEC design, installation, and monitoring standards and the local codes that adopt them.
- Independence — for design review, no commercial ties to the designer, EPC, or equipment suppliers.
- Responsiveness — the capacity to turn designs and proposals around within tender deadlines.
Many of the same criteria apply to choosing a testing partner, which AQ Electric covers in its article on how to choose a solar testing and commissioning partner.
AQ Electric’s Solar Engineering Consultation Services
AQ Electric for Power Solutions, founded in Jordan in 2019 and expanded to Egypt in 2021, provides solar engineering consultation services for EPC contractors and developers across the MENA region in three areas:
- Back-office full PV design — preliminary and feasibility design (site conditions, shading analysis, energy yield estimates, PVsyst reports, single-line diagrams, and layouts); detailed electrical and mechanical design (cable routing, string configurations, single-line diagrams, and structural layouts); bill of materials preparation; and technical documentation and as-built drawings.
- Tendering and proposals — bid document preparation, technical proposal development, and financial and commercial analysis including cost estimation and CAPEX/OPEX analysis.
- Full consultation services — site survey and feasibility study, conceptual and detailed design review, tender and contractor selection support, installation supervision and quality control, testing and commissioning support, energisation and grid connection assistance, and O&M planning.
Full details are on AQ Electric’s solar PV engineering and consultation services page.
Designs informed by the field
Engineering Backed by Testing Experience
AQ Electric’s engineers have delivered testing and commissioning on the 230 MWp Komombo plant in Aswan, Egypt, with China Energy Engineering Group (CEEC) and on the 120 MWp Wadi Ad Dawasir plant in Saudi Arabia with SEPCO – Power China. That experience of how plants behave once energised feeds directly into the designs, reviews, and yield assumptions AQ Electric produces.
Because AQ Electric also provides testing and commissioning services and FAT and SAT quality assurance, clients can keep design, verification, and handover with one technical team. AQ Electric operates under an ISO 9001, ISO 14001, and ISO 45001-certified management system from offices in Amman, Jordan and New Cairo, Egypt, with more than 1.0 GW of PV project experience. The full portfolio is on AQ Electric’s projects page.
Engineering That Holds Up in the Field
AQ Electric’s engineering, testing, and quality services across the MENA region.
📐Engineering & Consultation⚡Testing & Commissioning✓Quality Assurance (FAT & SAT)🔍Third-Party Inspection🔧Operation & Maintenance✉Speak to an Engineer
Frequently Asked Questions
What do solar engineering consultation services include?
They typically include site assessment and feasibility studies, preliminary and detailed electrical and mechanical design, PVsyst energy yield reports, single-line diagrams and layouts, bills of materials, technical documentation and as-built drawings, tender and proposal support, and independent design review.
What is a PVsyst report used for?
A PVsyst report simulates a plant’s energy production and documents the loss assumptions behind it. It provides the P50 and P90 yield estimates used in financial models, PPAs, and lenders’ debt sizing, and it is reviewed independently on financed projects.
What is back-office PV design?
Back-office PV design is outsourced design capacity for EPC contractors and developers: an external engineering team produces layouts, single-line diagrams, string configurations, yield reports, and bills of materials, so the client can price and deliver more projects without expanding its in-house team.
Why is independent design review important?
Design decisions are locked into a plant for decades. An independent review catches errors in string sizing, inverter loading, cable sizing, protection, monitoring, grid compliance, and yield assumptions while they are still cheap to correct.
How does the DC-to-AC ratio affect a solar design?
A higher DC-to-AC ratio increases energy in the morning and evening but clips more power at midday. It must be optimised for yield and cost, and checked for its effect on acceptance testing; Burns & McDonnell has documented that clipping above roughly 1.3–1.4 can complicate capacity tests on tracking plants.
How can engineering consultants help EPC contractors win tenders?
By preparing compliant bid documents and technical proposals, optimising the design and equipment selection, and supporting cost estimation and CAPEX/OPEX analysis, so the EPC can submit competitive, technically strong offers within tender deadlines.
What is different about designing solar plants in the Middle East?
Designs must account for extreme heat, dust and sand, wind, coastal corrosion, and increasingly demanding grid codes, all of which affect string sizing, inverter and cable derating, structures and trackers, cleaning access, and grid compliance.
Does AQ Electric provide solar engineering consultation services in MENA?
Yes. AQ Electric provides back-office PV design, PVsyst yield reports, bills of materials, tender and proposal support, design review, and full consultation services for EPC contractors and developers across Jordan, Egypt, Saudi Arabia, and the wider MENA region.
Design It Right Before You Build It
AQ Electric provides solar engineering consultation services across the MENA region — PV design, PVsyst yield reports, BOMs, tender support, and design review — from an engineering team that tests and commissions utility-scale plants alongside CEEC, SEPCO, and Power China.