AQ Electric runs both electroluminescence (EL) testing and infrared thermography on utility-scale solar plants across the MENA region, and one of the questions owners and EPC contractors ask us most often is which of the two they actually need. The honest answer is that EL testing vs thermal imaging is not a contest with one winner: the two methods see different things, work under different conditions, and answer different questions. This article compares them side by side — how each works, which defects each one finds or misses, what they cost in time and access, and how to combine them at factory acceptance, commissioning, warranty claims, and routine O&M.
Key takeaways
Thermal imaging (infrared thermography) inspects a plant in operation, in sunlight, and finds defects that produce heat: hotspots, failed bypass diodes, disconnected strings, and hot connections. It is fast and can cover a whole plant by drone. EL testing forward-biases modules, usually at night, and images the light the cells emit; it reveals cell-level damage such as microcracks, broken fingers, and PID that may not yet produce heat. In the EL testing vs thermal imaging decision, thermal imaging is the screening tool and EL is the diagnostic tool: scan the plant with IR, then use EL to confirm and document the root cause on the modules that matter — and use EL proactively at points where hidden cracks are likely, such as after transport and installation.
EL Testing vs Thermal Imaging: The Short Answer
If you need to know where a plant is losing energy, start with thermal imaging. If you need to know why a module is underperforming — or whether modules that look fine are already cracked — use EL testing.
- Thermal imaging works on the live plant under sunlight, covers large areas quickly, and detects anything that dissipates abnormal heat.
- EL testing needs the modules to be powered by an external supply, is usually done at night, and shows the internal condition of every cell in high detail.
The two are complementary. Most mature inspection programmes use thermal imaging for plant-wide screening and EL testing for targeted diagnosis, evidence, and acceptance.
How Thermal Imaging Works
To understand EL testing vs thermal imaging, start with what each instrument measures. Infrared thermography measures the surface temperature of modules, cables, and electrical equipment while the plant is operating. A healthy module heats evenly in the sun. When a cell, a cell group, or a connection cannot pass current normally, it dissipates energy as heat, and that heat shows up as a temperature anomaly in the thermal image.
The reference document is IEC TS 62446-3:2017, which defines outdoor thermographic inspection of PV modules and plants in operation, including requirements for the camera, ambient conditions, procedure, reporting, and personnel. Thermography under the specification calls for irradiance above 600 W/m² in the module plane, steady conditions, and low wind, because clouds and wind change the temperature pattern the camera sees.
Thermal imaging can be done with handheld cameras or from drones. Drones are the practical choice for utility-scale plants, because they can image an entire site in a short campaign; AQ Electric explains that approach in its article on drone inspection for solar PV plants, and the method in detail in its article on infrared thermography for solar PV. Handheld cameras remain essential for combiner boxes, inverters, and switchgear; EE Electronics, AQ Electric’s sister company, covers camera selection in its article on the thermal imaging camera for electrical inspection.
How EL Testing Works
Electroluminescence works the other way round. Instead of letting the sun generate current, an external power supply pushes current into the module in forward bias, so the cells behave like a large LED and emit faint near-infrared light. A camera sensitive to that wavelength captures the image. Active, well-connected cell areas glow; cracked, disconnected, or degraded areas appear dark.
IEC TS 60904-13:2018 specifies how to capture, process, and interpret EL images of PV modules measured in forward bias, and defines two bias levels — around the module’s short-circuit current (Isc) and around 10% of Isc — because some defects show more clearly at one current than the other. Because the emitted signal is weak compared with sunlight, field EL is usually carried out at night, although daylight EL techniques also exist.
EL can be performed on a single module in a factory or lab, on modules on site before installation, or string by string on an installed plant. AQ Electric covers the procedure in its article on electroluminescence (EL) testing for solar PV. Field teams use portable equipment such as the portable EL testing systems supplied in Jordan by EE Electronics.
EL Testing vs Thermal Imaging: Side-by-Side Comparison
The table below summarises EL testing vs thermal imaging across the factors that matter in the field.
| Factor | Thermal imaging (IR) | EL testing |
|---|---|---|
| What it measures | Surface temperature during operation | Light emitted by cells under forward bias |
| Reference standard | IEC TS 62446-3 | IEC TS 60904-13 |
| Conditions | Daylight, irradiance above 600 W/m², stable sky, low wind | Usually at night or in darkness; external power supply |
| Plant status | Plant operating normally | String or module isolated and back-fed |
| Coverage | Whole plant, fast (drone) | Targeted modules or strings; slower |
| Detail | Module and cell-group level | Cell and sub-cell level |
| Best at | Finding where heat and losses occur | Explaining why, and finding hidden damage |
| Main limitation | Misses defects that are not yet producing heat | Slower; needs access to strings and night work |
Which Defects Each Method Finds
The most useful way to settle EL testing vs thermal imaging for a specific problem is to look at the defect you are trying to find.
| Defect | Thermal imaging | EL testing |
|---|---|---|
| Microcracks (new, still connected) | Usually not visible | Clearly visible |
| Cracks that isolate cell areas | Visible as warm cells once electrically active | Visible as dark areas |
| Broken fingers and busbar defects | Rarely visible | Visible |
| Potential-induced degradation (PID) | Visible as patterns of warm cells in affected modules | Visible as darkened cells, often toward the frame |
| Failed or shorted bypass diodes | Clearly visible as warm substrings | Visible as dark substrings |
| Hotspots from shading or soiling | Clearly visible | Not applicable (no sunlight) |
| Open-circuit strings and disconnected modules | Clearly visible | Visible if the string is back-fed |
| Hot connectors, fuses, and terminals | Clearly visible | Not applicable |
| Soldering and manufacturing defects | Sometimes visible | Visible |
The pattern is clear. Thermal imaging finds anything that is already costing energy or creating a safety risk through heat, including balance-of-system faults EL cannot see. EL testing finds cell damage before it becomes a heat problem, and it gives the clearest evidence of what is wrong inside a module. The defects themselves are explained in AQ Electric’s article on common PV module defects.
Why Hidden Cracks Matter
A microcrack that is still electrically connected may cost almost nothing on day one. Thermal cycling, wind, and mechanical load can open it over time, isolating part of the cell and creating a hotspot and power loss. That is why EL testing is most valuable at the points where cracks are introduced — manufacturing, transport, and installation — when the evidence can still be used to reject modules or support claims.
When to Use Each Method
The right answer to EL testing vs thermal imaging changes with the project stage, because the risks change with it.
| Project stage | Recommended method | Why |
|---|---|---|
| Factory acceptance | EL on a sample of modules | Detects manufacturing defects before shipment |
| Arrival on site | EL on a sample from each shipment | Detects transport damage while the supplier is still liable |
| After installation | EL on a sample of installed strings | Detects installation damage before handover |
| Commissioning | Thermal imaging of the full plant, EL to confirm findings | Establishes a baseline and proves the plant is defect-free at handover |
| Routine O&M | Periodic drone thermal imaging | Finds new faults and losses across the whole plant |
| Warranty claims | EL on affected modules, supported by IR and IV data | Provides root-cause evidence suppliers accept |
| After storms or extreme events | Thermal imaging, then EL on suspect areas | Quickly locates damage, then confirms it |
| Acquisition or refinancing | Thermal imaging of the full plant, EL sampling | Gives buyers and lenders an objective condition assessment |
At factory and site acceptance, EL sampling fits naturally into the inspection plan AQ Electric describes in its article on FAT vs SAT in solar PV projects. At handover, both methods support the wider test programme set out in the solar PV commissioning process and IEC 62446-1. For transactions, they form part of solar PV technical due diligence and solar bankability testing.
Combining EL and IR in One Workflow
For most operating plants, the question is not EL testing vs thermal imaging but how to sequence them. A practical workflow looks like this:
- Screen the plant with drone thermal imaging under conditions that meet IEC TS 62446-3, and classify every anomaly by type and severity.
- Fix the obvious faults first — open strings, blown fuses, hot connectors, and failed diodes — which thermal imaging pinpoints directly.
- Measure the affected strings with IV curve tracing to quantify the power loss; AQ Electric explains the method in its article on IV curve tracing for solar PV.
- Run EL on the modules that need a diagnosis — repeated hotspots, unexplained losses, suspected PID or cracking — to identify the root cause.
- Document and act — replace, claim, or monitor the modules, and track the trend in later campaigns.
Combining the three data sets — thermal anomaly, measured power loss, and EL image — produces evidence that is hard to dispute, whether the audience is a module supplier, an EPC contractor, an insurer, or a lender. It also feeds directly into the plant’s solar performance ratio analysis and the wider strategy described in AQ Electric’s article on solar PV plant operation and maintenance.
EL and IR in Gulf and MENA Conditions
The region’s climate affects both sides of the EL testing vs thermal imaging decision. High irradiance makes it easy to meet the thermography threshold for most of the year, but very high ambient temperatures, wind, and dust can reduce image quality and must be recorded and managed. Heavy soiling creates hotspots of its own, so cleaning status should be noted before thermal results are interpreted.
EL testing in the region is usually planned as night work, which avoids daytime heat for field teams but needs careful safety planning and access to string connections in the dark. Extreme daily temperature swings in desert climates also make hidden microcracks more likely to grow over time, strengthening the case for EL at acceptance.
AQ Electric covers country-specific requirements in its articles on solar PV testing services in Saudi Arabia, solar testing services in Egypt, solar PV testing services in Jordan, and solar PV testing services in the UAE, and the regional pipeline in its MENA solar market outlook.
Common Mistakes
Most mistakes in planning EL testing vs thermal imaging come from expecting one method to do the other’s job.
- Treating a clean thermal survey as proof of no damage. New microcracks often do not show in thermal images; EL is needed to see them.
- Running thermography in the wrong conditions. Low irradiance, passing clouds, or strong wind produce misleading results.
- Using EL for plant-wide screening. It is slow and labour-intensive at plant scale; target it where it adds the most value.
- Skipping EL at acceptance. Once modules are installed and the plant is handed over, proving that cracks came from transport or installation becomes much harder.
- Reporting images without classification. Findings should be classified by type and severity, with module locations, so the O&M team can act on them.
- Relying on one data set for warranty claims. Suppliers respond best to combined EL, IR, and IV evidence.
Independent inspection avoids many of these mistakes; AQ Electric explains why in its article on third-party inspection for solar PV.
How AQ Electric Delivers EL and Thermal Inspections
AQ Electric for Power Solutions, founded in Jordan in 2019 and expanded to Egypt in 2021, treats EL testing vs thermal imaging as a combination rather than a choice, and provides both inspection methods for EPC contractors, developers, owners, and O&M operators across the MENA region:
- EL testing at the factory, on arrival, after installation, at commissioning, and for warranty claims — see AQ Electric’s EL testing services.
- Drone thermal inspection of complete plants with classified anomaly reports — see AQ Electric’s drone inspection services.
- IV curve tracing to quantify losses on affected strings — see AQ Electric’s IV curve tracing services.
Field experience
Thermal Drone Inspection in Aswan
AQ Electric has carried out thermal drone inspection for ACWA Power and NOMAC in Aswan, Egypt, and has delivered testing and commissioning on the 230 MWp Komombo plant with China Energy Engineering Group (CEEC) and on the 120 MWp Wadi Ad Dawasir plant in Saudi Arabia with SEPCO – Power China. Across more than 500 MW commissioned, our teams use EL, thermography, and IV data together to find faults and prove plant condition.
Because AQ Electric also provides testing and commissioning services, inspection findings go straight into the handover and punch-list process. AQ Electric operates under an ISO 9001, ISO 14001, and ISO 45001-certified management system from offices in Amman, Jordan and New Cairo, Egypt, with more than 1.0 GW of PV project experience. The full portfolio is on AQ Electric’s projects page.
Find Faults Before They Cost You
AQ Electric’s inspection and testing services across the MENA region.
🔬EL Testing🚁Drone Inspection📊IV Curve Tracing⚡Testing & Commissioning🔧Operation & Maintenance✉Speak to an Engineer
Frequently Asked Questions
What is the difference between EL testing and thermal imaging?
Thermal imaging measures heat from modules and equipment while the plant operates in sunlight, and finds hotspots, failed diodes, open strings, and hot connections. EL testing back-feeds current into modules, usually at night, and images the light emitted by the cells, revealing microcracks, broken fingers, PID, and other cell-level damage.
Which is better, EL testing or thermal imaging?
Neither is better in general. Thermal imaging is the best tool for fast, plant-wide screening; EL testing is the best tool for detailed diagnosis and for finding hidden cell damage. Most inspection programmes use both.
Can thermal imaging detect microcracks?
Only once they isolate part of a cell and start producing heat. New, still-connected microcracks are usually invisible in thermal images but clearly visible in EL images.
Why is EL testing done at night?
The light emitted by cells under forward bias is weak compared with sunlight, so darkness gives the clearest images. Daylight EL techniques exist, but night-time EL remains the most common approach in the field.
What standards apply to EL and thermal inspections?
IEC TS 62446-3 covers outdoor infrared thermography of PV modules and plants, including a minimum irradiance of 600 W/m². IEC TS 60904-13 covers capturing, processing, and interpreting EL images of PV modules in forward bias.
When should EL testing be done on a solar project?
The most valuable points are factory acceptance, arrival on site, after installation, and commissioning, when cracks from manufacturing, transport, or installation can still be rejected or claimed. EL is also used later to diagnose underperforming modules and support warranty claims.
Can drones perform EL testing?
Drone-based EL is being developed and used in some projects, combined with power supplies that back-feed strings. Drone thermal imaging is far more widespread, and most field EL is still carried out with ground-based cameras.
Does AQ Electric offer EL testing and thermal imaging in MENA?
Yes. AQ Electric provides EL testing, drone thermal inspection, and IV curve tracing for solar plants across Jordan, Egypt, Saudi Arabia, and the wider MENA region, at acceptance, commissioning, and in operation.
See What Your Plant Is Hiding
AQ Electric combines EL testing, drone thermal imaging, and IV curve tracing to find faults, prove plant condition, and support warranty claims across the MENA region — backed by work with ACWA Power, NOMAC, CEEC, SEPCO, and Power China.